StarWind Maintenance Mode Overview
Posted by Ivan Talaichuk on October 19, 2017
No ratings yet.

Howdy, folks! I would like to start my tale with a little backstory regarding usefulness which the “maintenance mode” brings to us. And in order to do that, I’ll start from the times when updates have led to the downtime for production.

That’s not a secret for anyone that any production environment sometimes needs to be maintained. It could either be a software update or a hardware reconfiguration. To do this, the administrator should stop the production server for a certain period of time, and this may affect the reliability of the production environment. For example, the fault tolerance level can be decreased, as well as the performance. This is especially critical for small infrastructures which consist of 2 nodes.

So, let’s take a closer look at StarWind maintenance mode and what it delivers to us. First of all, it eliminates the downtimes caused by the planned nodes shutdowns and thus, allows keeping nodes in the pre-synchronized state so that synchronization resumption would not be needed. As a result, the system doesn’t experience any performance and availability degradation.

Enable the maintenance mode on HAimage

(more…)

Please rate this

vSphere 6.5: HA & DRS improvements. Part 2
Posted by Askar Kopbayev on March 3, 2017
5/5 (1)

In Part II we will review the remaining improvements in vSphere Availability and Resource Management brought by vSphere 6.5.

Challenge: HA Restart priorities are not flexible enough

Description

Modern applications can be very complex and may consist of more than one server. Very often multi-tier applications require specific restart order, e.g. classic scheme DB – App – Web.  For instance, if an application server powers on before the database server the application will fail to start. To make it worse, there is no guarantee that the application server will automatically recover after DB server is powered on.  Sometimes the application server will have to be rebooted to restore the service. Moreover, there could be inter-application dependencies which make the situation even more complicated.

DRS in vSphere 6.5 view

(more…)

Please rate this

Storage HA on the Cheap: Fixing Synology DiskStation flaky Performance with StarWind Free. Part 3 (Failover Duration)
Posted by Vladislav Karaiev on February 17, 2017
5/5 (10)

We are continuing our set of articles dedicated to Synology’s DS916+ mid-range NAS units. Remember we don’t dispute the fact that Synology is capable of delivering a great set of NAS features. Instead of this, we are conducting a number of tests on a pair of DS916+ units to define if they can be utilized as a general-use primary production storage. In Part 1 we have tested the performance of DS916+ in different configurations and determined how to significantly increase the performance of a “dual” DS916+ setup by replacing the native Synology DSM HA Cluster with StarWind Virtual SAN Free.

Synology DS916 and StarWind

(more…)

Please rate this